日本CC-LINK电缆

   上海欧亚线缆有限公司主要从事日本CC-LINK电缆的销售。主要型号有:CCNC-

SB110SF-5,CCNC-SB110H+PW,CCNC-SB,CCNC-SBH。 

1961PEAK放大镜系列

 

    

1961

1962

1964

1996

放大倍数

10X

15X

22X

30X

直径

24mm

19mm

19mm

7mm

   

φ34.5*41.5

φ36*33

φ28.5*30

φ37*20

                             

    

1975

   

1983

放大倍数

7X

 

放大倍数

10X

直径

18mm

 

直径

20mm

   

24mm

 

   

32mm

                                        

  

2016

 

   

2037

 

   

2044

放大倍数

15X

 

放大倍数

30X

 

放大倍数

8X-16X

直径

13mm

 

直径

7mm

 

  

45*65mm

  

20mm

 

   

30*19mm

 

 

 

该公司产品分类: 工场型显微镜 泛用检测仪器类 耐黄变试验箱 沙尘试验箱 紫外线耐候试验机 高低温冷热冲击试验箱 恒温恒湿试验箱 精密烤箱系列 鼠标转轴试验机 笔记本耐压试验机 手机滑盖试验机 手机翻盖试验机 全自动开关、按键试验机 全伺服自动控制插拔力试验机 NB前后摇摆试验机 NB转轴试验机 漆膜弯曲试验机系列 杜邦式冲击试验机系列 湿膜涂布器系列 破坏式干膜膜厚测试仪

厂家供应GW9-12型户外高压隔离开关 柱上隔离开关 10KV高压开关

                                                                              GW9-12型户外高压隔离开关
   
 
一、结构简介
GW9-12型户外单极隔离开关(以下简称为开关)适用于10千伏高压输配电线路上,
用以切断和闭合无负载有电压的单相或三相电路。
 开关供三相线路系统单相使用,其结构简单,经济,使用方便。
  开关的额定电流有:220;400;600和1000安。它们皆由底座,支柱绝缘子,导电部分和机构部分组成。采用闸刀式结构分合闸达到切断和闭合线路。每相闸刀由两片导电刀片组成,刀片两侧装有压缩弹簧,调节弹簧的高度可以得到开关闸刀所需要的接触压力。开关分合闸时用绝缘钩棒操作机构部分便可以进行合闸运动。
二、使用环境条件和主要技术条件
     1.使用环境条件:
1.1海拔高度不超过1000米;
1.2环境温度:最高环境温度不高于+40℃;最低环境温度不低于-30℃;
  1.3户外风速不超过35米/秒;
1.4地震烈度不超过8级;?
1.5安装场所应无严重影响开关绝缘和导电能力的气体、蒸汽、化学性质的沉淀、盐雾、灰尘垢污、及其他爆炸物、侵蚀性介质。
   1.6安装场所应无频繁的剧烈振动。厂家供应辉能电气GW9-12型户外高压隔离开关 高压开关浙江辉能电气有限公司是一家具有现代化生产规模的企业,公司主要经营高低压电气成套设备,高低压电气元器件等。公司成立以来,一直致力于专业化发展道路,凭借专业的技术力量,国内外先进设备,创新的理念,丰富的创造经验,齐全的产品品种,已成为电气设 备制造业骨干企业之一。       公司秉承“质量至上,信誉为本,的企业宗旨,以市场为向导,以质量求发展,以管理求效益,以科技创新的经营理念。在新的产品的开发上不断更新,立足市场,提供优质的产品和一流的服务。公司先后通过了ISO9001国际质量管理体系认证,CCC认证,产品经电力工业部,电力科技研究院检测合格。
该公司产品分类: 真空断路器

SK100型(数控)锁管机

 我厂研制生产的SK-100型锁管机适用于工农业和工程机械液压传动用高压胶管、纤维管、塑料管总成的扣压加工。具有扣压范围广、精度高(采用PLC控制)、自动化程度高、易操作、好维修等优点。 

二 主要技术特征

 1.扣压钢丝胶管内径: φ4~φ51IVmm 工业管内径: 最大89mm 

2.标尺精度: 0.01mm 

3. 功 率: 4KW                           4. 电 压: 380V               5. 最大扣压力: 252吨 

6. 转 速: 1440r/min                     7. 油泵排量: 10ml/rad      8. 外形尺寸: 858×910×1550(mm) 

9. 重 量: 800Kg                       10. 最大开口直径: +68mm

 

该公司产品分类: 消防灌装 锁管机 试压泵

NI Lookout

  • lookout
  • 带有Web功能的自动化软件-Lookout 基于物体的架构
  • 方便快速的网络连接
  • Web控制与监视
  • 事件驱动处理
  • 确保生产效率大幅度提高
  • 工业标准OPC接口

National Instruments公司的lookout,是工业控制市场上最方便易用的HMI/SCADA软件。其简便的联网性能,及与当今所使用的大量硬件迅速连接的特性,使Lookout在大幅度提供使用者开发效率的同时,还降低了工程设计和维护的费用。您只需要连接物体,就可以完成分布式I/O和PLC连接,快车增加控制逻辑,报警计算和用户界面的开发。Lookout为应用程序提供可缩放的架构,从简单的HMI到大型复杂的SCADA均能轻松胜任。

KT5-466-142KENTA指针千分表0-5MM

产品描述:
*硬质合金测量头
 
*不锈钢的安装杆
 
*表盘双向刻度显示
 
*转动刻度盘可调0
 
*具有防震功能

HFKLT2-2 HFKLT2-Ⅱ双向拉绳开关HFKLT2-2 HFKLT2-Ⅱ

双向拉绳开关系我公司组织科研人员开发研制的新一代产品,可用于胶带运输机现场。当发生紧急事故时,便启动本机使运输机立即停机防止事故的扩大。本产品由于安装方便、开关性能,在胶带运输机中得到广泛应用。

TXMK-II高压模拟开关/高压模拟断路器

一、用途: TXMK-II型高压断路器模拟装置主要用于继电保护装置的整组试验以及在备用电源自投装置试验等项目中替代真实的高压断路器(根据需要,可灵活地模拟五组断路器)。在整组试验时模拟高压断路器的跳、合闸,以避免由于重复的整组试验造成高压断路器反复分合带来不良影响,本模拟装置为微机继电保护测试系统的配套产品,特别在新建电厂、变电站的高压断路器没调好或未投直流电源的情况下,使用本装置进行继电保护试验将不受外界因素影响,从而缩短调试时间,提高试验工作效率。生产厂家和科研单位等部门使用该装置将会事半功倍。其它类似运用可根据具体情况具体处理。 二、模拟装置原理 该模拟装置采用单片微机作为控制核心,实现模拟高压断路器跳、合闸时间设置、输入信号逻辑控制等功能,从而模拟高压断路器的跳、合闸动作,同时提供一组隔离的直流电压输出,装置操作简单、。 技术指标介绍:技术特点▲供电电源AC220V±10%▲模拟实际高压断路器动作特性▲电源DC220V/110V任选▲跳合闸阻抗:400Ω、200Ω、100Ω、50Ω任选▲合闸时间:20~200ms▲跳闸时间:20~100ms▲接点容量为AC220V/5A

TH-8100S 伺服电脑式万能材料试验机100KN拉力机 100KN拉力试验机 拉力机

专业生产万能材料试验机 详情请询18913135992冯婷 QQ1470077205技术规格:

一、 主要技术参数:

1、 最大试验力:100KN;

2、 度等级:优于1级;

3、 负荷测量范围:0.2%—100%FS;

4、 试验力示值允许误差极限:示值的±1%以内;

5、 试验力示值分辨率:最大试验力的1/±200000;

6、 变形测量范围:0.2%—100%FS;

7、 变形示值误差极限:示值的±0.50%以内;

8、 变形分辨力:最大变形的1/80000

9、 位移示值误差极限:示值的±0.5%以内;

10、 位移分辨力:0.05µm

11、 力控速率调节范围:0.01-10%FS/S;

12、 力控速率控制精度:设定值的±1%以内;

13、 变形速率调节范围:0.02—5%FS/S;

14、 变形速率控制精度:设定值的±1%以内;

15、 位移速度调节范围:0.5—500mm/min

16、 位移速率控制精度:速率<0.1mm/min时,设定值的±1.0%以内;速率≥0.1mm/min时,设定值的±0.2%以内;

17、 恒力、恒变形、恒位移控制范围:0.5%--100%FS;

18、 恒力、恒变形、恒位移控制精度:设定值≥10%FS时,设定值的±0.1%以内;设定值<10%FS时,设定值的±1%以内;

19、 试验宽度:400×400mm

20、 拉伸空间距离:1100mm

21、 主机外型尺寸(长×宽×高):840×460×2050(mm)

22、 使用电源:三相220V 50Hz;

23、 机台重量:约600kg;

二、 控制及数据处理软件功能特色:

1、 的芯片集成技术,专业设计的数据采集放大系统,具有集成度高、稳定、使用方便等优点。控制软件能实现自动求取抗拉强度、屈服强度、断裂强度、弹性模量、延伸率等检测数据,开放式公式编辑能自动计算试验过程中任一指定点的力、应力、位移、变形等数据结果。对试验过程的控制和数据处理符合相应金属材料与非金属材料国家标准的要求。

2、 控制方式:定速度、定位移、定荷重、定荷重增率、定应力、定应力增率、定应变、定应变增率等控制方式可选;

3、 自动清零:试验开始后,测量系统自动调零;

4、 自动换档:根据负荷大小自动切换到适当的量程,以确保测量数据的度;

5、 自动存盘:试验数据和试验条件自动存盘,杜绝因忘记存盘而引起的数据丢失;

6、 批量试验:对相同参数的试样,一次设定后可顺次完成一批试验;

7、 显示方式:数据与曲线随试验过程动态显示;

8、 曲线遍历:试验完成后,可对曲线进行再分析,用鼠标找出试验曲线上各点对应的数据;

9、 曲线选择:可选择应力-应变、力-位移、力-时间、位移-时间等曲线进行显示和打印;

10、 单位切换:力量单位:(g、kg、N、lb)、应力单位:(kg/mm2、N/mm2、Mpa、lbf/in2)位移单位:(m、mm、in)

11、 试验报告:可按用户要求的格式对试验报告进行编程和打印,并可导出EXCEL文件;

12、 安全保护:超过最大负荷的2~10%时,自动实现安全保护;

13、 可自动检测、计算试样的机械性能指标,也可人工干预分析过程,根据相关标准的要求对自动分析结果进行修正,以提高数据的度;

随机标准配件:

1、 荷重传感器:美国AMCELLDS高精度荷重元,100KN 一个;

2、 位移感应系统:日本光电编码器感应全程位移编码器 一套;

3、 数据采撷卡:THM2000 64位闭环测量控制主板 一张;

4、 测试软件:THM2000 英文/中文简体/繁体三合一测量控制系统 一套;

5、 动力系统:进口交流伺服马达及控制驱动系统 一套;

6、 传动系统:台湾VGM行星减速箱及台湾ABBA精密滚珠丝杆 一套;

7、 测试治具:依客户试样制定测试治具 一套;

其他选配件:(费用另计)

1、 数据分析专用电脑:联想商用机 一台

2、 测试报表输出:打印机 一台

该公司产品分类: 工程塑料试验机 转轴扭力试验机 电线扭转试验机 U型拖链试验机 电线弯曲试验机 纸箱抗压试验机 电池片剥离试验机 常用测试夹具 医疗制品检测设备 纸品包装运输检测设备 胶粘制品检测设备 太阳能光伏检测设备 电线电缆检测设备 橡塑制品检测设备 金属制品检测设备 动态疲劳寿命试验机 液压万能材料试验机 电子万能材料试验机 万能材料试验机 万能材料试验机

人白介素-1(IL-1)酶免试剂盒(ELISA KIT)

rat anti – human interleukin 1人白介素-1(il-1)酶免试剂盒(elisa kit) collect sample – secretion package size: 96 determinations catalogue no.: qrct – 322101eia \ utl storage: 2 - 8 °c i. introduction producing of il-1 cell the il-1 is main to be produced by cell;in addition and almost allly there is cell, such as the t that b cell, nk the cell, outside educate cell, horniness cell, tree cell, star polygon cell, fiber cell, neutral grain cell, inside skin the cell and smooth muscle cell can all produce the il-1. although its amino acids is in proper order to only reach 26% of , however the il-1 cell of similar to il-1 the β is with the affinity that same to join together in α surface suffer, and develop the same biology function.the il-1 suffers the il-1 the r to almost exsits in all have the cell the il-1 r of the surface, each cell the number and does not wait, little then several ten( such as the t cell), much and then several thousand.special function that il-1 although not extensive used for the body research, its make it have the foreground of the person in the clinical application aspect to immune system.moreover, because of the il-1 too the various and pathologic process of the and machine, therefore study the il-1 repress the thing may also have the actual meaning.now already the gram outs the il-1 suffer the anti- the il-1 for activity for, that material can outside inside closing the il-1, is first kind than ideal to close the factor. ii. reagents materials provided with the kits : 􀂄 coated microtitration strips 96 wells. 􀂄 standard 0, 25, 50, 100, 250, 500 pg/ml, 1 ml/vial, lyophilized. 1 set. 􀂄 enzyme conjugate solution, 6 ml. 􀂄 chromogen solution a, 6 ml. 􀂄 chromogen solution b, 6 ml. 􀂄 stopping solution (1n hcl), 6 ml. 􀂄 wash concentrate,50 ml( x 20). materials required but not provided : 􀁺 precision pipettes: 0.10, 0.20, and 1.0 ml. 􀁺 disposable pipette tips. 􀁺 distilled water. 􀁺 vortex mixer or equivalent. 􀁺 absorbent paper or paper towels. 􀁺 microtiter plate shaker 􀁺 graph paper. 􀁺 a microtiter plate reader with a bandwidth of 10nm or less and an optical density range of 0-2 od or greater at 450 nm . - page 1- for informational use only ▪ do not use for performing assay ▪ refer to most current package in-sert accompanying testkit rat anti – human interleukin 1 collect sample – secretion package size: 96 determinations catalogue no.: qrct – 322101eia \ utl storage: 2 - 8 °c iii. storage of test kit and instrumentation unopened test kits should be stored at 2-8°c upon receipt and the microtiter plate should be kept in a sealed bag with desiccants to minimize exposure to damp air. opened test kits will remain stable until the expiration date shown, provided it is stored as described above. a microtiter plate reader with a bandwidth of 10nm or less and an optical density range of 0-2 od or greater at 450nm wavelength is acceptable for use in absorbance measurement. iv. assay procedure 1. secure the desired number of coated wells in the holder. 2. dispense 100 μl of standards and specimens into appropriate wells. 3. dispense 50 μl of enzyme conjugate reagent into each well. gently mix for 15 seconds. 4. incubate at 18-25 °c for 90 minutes. 5. remove the incubation mixture by emptying plate contents into a suitable waste container. 6. rinse and empty the microtiter wells 5 times with distilled or deionized water. (mix 50ml of washing buffer 20x with 950ml of distilled water.) 7. strike the wells sharply onto absorbent paper to remove residual water dr-oplets. 8. dispense 50 μl of color a and color b reagent into each well. gently mix for 5 seconds. 9. incubate at 18-25 °c for 15 minutes. 10. stop the reaction by adding 50 μl of stop solution to each well. 11. gently mix for 30 seconds. it is important to make sure that all the blue color changes to yellow color completely. 12. using a microtiter plate reader, read the optical density at 450 nm within 30 minute. v. important notes the wash procedure is critical. insufficient washing will result in poor precision and falsely elevated absorbance readings. it is recommended that if manual pipetting is used, no more than 32 wells be used for each assay run, since pipetting of all standards, specimens and controls should be completed within 3 minutes. a full plate of 96 wells may be used if automated pipetting is available. duplication of all standards and specimens, although not required, is recommended. vi. example of standard curve calculate the average absorbance values (a450) for each set of reference standards, control, and samples. construct a standard curve by plotting the mean absorbance obtained for each reference standard against its concentration on linear graph paper, with absorbance on the vertical (y) axis - page 2- for informational use only ▪ do not use for performing assay ▪ refer to most current package in-sert accompanying testkit rat anti – human interleukin 1 collect sample – secretion package size: 96 determinations catalogue no.: qrct – 322101eia \ utl storage: 2 - 8 °c and concentration on the horizontal (x) axis.using the mean absorbance value for each sample, determine the corresponding concentration of in from the standard curve. results of a typical standard run with optical density readings at 450nm shown in the y axis against concentrations shown in the x axis. this standard curve is for the purpose of illustration only, and should not be used to calculate unknowns. each user should obtain his or her own data and standard curve. vii. calculation of results the minimum detectable concentration of il1 in this assay is estimated to be 1.0pg/ml. viii. limitations of the procedure reliable and reproducible results will be obtained when the assay procedure is carried out with a complete understanding of the package in-sert instructions and with adherence to good laboratory practice. the wash procedure is critical. insufficient washing will result in poor precision and falsely elevated absorbance readings. the results obtained from the use of this kit should be used only as an adjunct to other diagnostic procedures and information available to the physician. - page 3-

人白介素-1(il-1)酶免试剂盒(elisa kit)

最新产品

热门仪器: 液相色谱仪 气相色谱仪 原子荧光光谱仪 可见分光光度计 液质联用仪 压力试验机 酸度计(PH计) 离心机 高速离心机 冷冻离心机 生物显微镜 金相显微镜 标准物质 生物试剂